Gun Tilt Refinement

Forums

Hi, I have a question about gun tilt refinement in FREALIGN.
I tried different values for TX and TY (even at 0.2 mrad instead of 0.02), but always got exactly the same resolution number and FSC curve.

In mult_hreconstruct_n.com file, I put in:
1.,${dstep},60.0,${thresh},${cs},${kV},0.2,0.2 !RELMAG,DSTEP,TARGET,THRESH,CS,AKV,TX,TY

How can I be sure the program actually reads in the TX and TY values I specified?

Thanks!

Rui

The TX, TY values should be printed as part of the header section of the output parameter file. Did the output maps also look exactly the same for different values?

In reply to by niko

Hi, Niko,

The output files such as 13pf_2_r1_mult_reconstruct.log and 13pf_2_r1.res contain the correct TX, TY values I put in, but the output maps look close to identical.
I only tried different TX TY values for the reconstruction step, but using the same parameter file from refinement.